Whether you own a Pueblo-style home with parapet walls and canales in Albuquerque, Rio Rancho, Los Lunas, or Santa Fe, or manage a commercial building, choosing a durable flat roof in New Mexico requires understanding how extreme high-desert physics affect single-ply membranes. Explore our unbiased engineering breakdown comparing Versico, Carlisle, GAF, Elevate (formerly Firestone), Johns Manville, Duro-Last, and Sika Sarnafil—plus why .060-mil TPO is the undisputed sweet spot and how to protect your roof from destructive "free estimate" core cuts.
With 310+ sunny days and thin high-altitude atmosphere, New Mexico roofs absorb 30% to 45% more ultraviolet radiation than roofs at sea level. Cheap membranes and asphaltic roofs bake, chalk, and crack prematurely.
A roof surface in Albuquerque can hit 165°F on a dark roof in the afternoon and drop to 55°F overnight. White reflective TPO keeps rooftop temperatures near ambient air temp while hot-air welded seams expand and contract monolithically without splitting.
July–September monsoons dump torrential rain onto enclosed parapet roofs. Unlike acrylic coatings that re-emulsify in standing water or modified bitumen seams that weep, properly welded TPO seams are 3x to 4x stronger than the sheet itself and impervious to ponding water.
East Mountain canyon winds and spring hailstorms demand high-tensile polyester scrim reinforcement, mechanical aluminum termination bars, and high-density cover boards underneath the membrane.
Property owners shopping for a budget-friendly flat roof are often confused when one contractor quotes 45-mil TPO, another pushes 60-mil TPO, and a third insists on 80-mil TPO. In single-ply roofing, 1 "mil" equals one-thousandth of an inch (0.001"). Here is the transparent manufacturing and field-engineering truth about why 60-mil TPO is the clear winner for New Mexico residential and commercial roofs.
Nationwide, 60-mil TPO accounts for the vast majority of commercial and residential production volume at plants run by Versico, Carlisle, and GAF. Because extruder lines run 60-mil continuously in massive volume, the raw material cost difference between 45-mil and 60-mil is typically only $0.18 to $0.32 per sq. ft.—meaning you get 33% more total membrane thickness and ~45% more UV weathering layer for a tiny fraction of total project cost.
Every TPO membrane has three layers: a dark bottom ply, a central polyester reinforcing mesh ("scrim") for tear strength, and a white UV-stabilized top weathering ply. New Mexico's intense UV slowly erodes the top ply over decades (roughly 0.7 to 1.0 mil per year). Once UV reaches the scrim, the roof fails. 60-mil TPO features ~22–26 mils of top cap over the scrim (vs. only ~15–17 mils on 45-mil), adding 7 to 10+ extra years of real-world NM lifespan.
While 80-mil TPO sounds great on paper, it is extremely stiff and rigid. On New Mexico residential flat roofs with tight thru-wall scuppers (canales), narrow parapet walls, tight inside corners, and residential pipe clusters, stiff 80-mil resists folding cleanly and can cause "tenting" or bridging at T-joints. 60-mil TPO hits the mechanical sweet spot: rugged enough to resist hail and foot traffic, yet supple enough to detail and hand-weld flawlessly around complex Southwestern architecture.
Why TOS (Thickness Over Scrim) Matters: ASTM D6878 requires a minimum of only 15 mils over the scrim. Leading 60-mil membranes (like Versico VersiWeld) deliver 24+ mils over the scrim—protecting the structural core from New Mexico's relentless UV rays.
60-mil TPO is the gold standard for Albuquerque, Rio Rancho, Los Lunas, and Santa Fe residential flat roofs and commercial warehouses. Because manufacturers produce 60-mil in the highest volume, the price-per-mil of UV protection is unmatched. It welds reliably around complex residential canales and scuppers without the stiffness penalty of 80-mil.
| Spec Metric | .045 Mil TPO | ★ .060 Mil TPO (Winner) | .080 Mil TPO |
|---|---|---|---|
| Top Weathering Cap (TOS) | ~15–17 mils (Minimum) | ~22–26 mils (+45% thicker cap) | ~30–34 mils |
| Max Manufacturer NDL Warranty | 15 Years (Typically) | 20 to 25 Years | 25 to 30 Years |
| Installed Project Cost Difference | Baseline (-4% to -6% total) | Sweet Spot Baseline | +15% to +24% higher (Material + Labor) |
| Best NM Application | Short-term flips / sheds only | 95% of NM Homes & Commercial Buildings | Hospitals, Data Centers, Extreme Hail Zones |
For decades, New Mexico flat roofs relied on hot-mopped Built-Up Roofs (BUR / tar and gravel) or torch-down modified bitumen. While thick, asphalt-based roofs absorb massive solar heat, crack under UV stress, and trap moisture inside parapet assemblies. The single-ply revolution transformed low-slope roofing through four distinct generations:
Black EPDM rubber proved flexible, but in New Mexico it reached 170°F+ in summer, baking homes and cooking glue-based seams. Early PVC membranes were white and weldable, but relied on liquid plasticizers that leached out under desert UV, turning brittle and shattering during hailstorms.
Thermoplastic Polyolefin (TPO) was invented to merge ethylene-propylene rubber and polypropylene without liquid plasticizers. However, early manufacturers used wildly different flame retardants, brominated additives, and inadequate UV antioxidants. Some early players—most notoriously J.P. Stevens—suffered systemic field failures.
Leading tier-one manufacturers (Versico, Carlisle, GAF, Elevate, JM) revolutionized TPO chemistry by introducing high-molecular-weight Hindered Amine Light Stabilizers (HALS) and proprietary antioxidant packages like OctaGuard XT™—delivering membranes that withstand extreme high-altitude heat and UV more than 4x beyond ASTM minimums.
When evaluating flat roof manufacturers, history matters. During the late 1990s and 2000s, J.P. Stevens (Stevens Roofing Systems) was a widely installed single-ply manufacturer marketing Stevens EP and Stevens TPO membranes across the Southwest and nationwide.
Many residential and commercial buildings in Albuquerque, Rio Rancho, and Santa Fe still have old J.P. Stevens membranes sitting on them today—either exposed and heavily crazed, or hidden underneath layers of silver or white elastomeric acrylic/silicone bucket coatings applied by previous owners trying to stop leaks.
Important: You cannot reliably heat-weld new patches onto a degraded J.P. Stevens membrane because the oxidized polymer is brittle and delaminates. Identifying whether your existing single-ply roof is an orphan J.P. Stevens system is a critical part of our diagnostic inspection.
Before you allow any roofing salesperson onto your flat roof with a core knife or hole saw during a "Free Estimate," read how intrusive inspections work—and why poor core patching is one of the leading causes of sudden, unclaimed roof leaks in New Mexico.
A core sample is an intrusive surgical cut all the way through your waterproofing membrane, cover board, insulation layers, and vapor retarder right down to the structural wood or metal deck. Roofers perform core cuts to see how many roofs are stacked on your building (building code prohibits more than 2 roof layers) and whether the insulation is wet.
Properly repairing and thermally sealing a multi-layer core cut on an aging TPO, PVC, modified bitumen, or tar-and-gravel roof takes significant time, surface prep, specialized primers, insulation replacement plugs, and heat-welded or three-coursed patches—far more time and material cost than a salesperson on a quick "Free Estimate" is willing or equipped to invest.
Instead, many estimators cut a hole, look inside, shove the plug back in, and slap a glob of hardware-store caulk, cold mastic, or peel-and-stick tape over the cut.
A smart homeowner invites 3 or 4 roofing companies out for "Free Estimates." Three of those roofers cut their own core samples in different spots and hastily smear caulk over them. Two weeks later, a New Mexico thunderstorm hits. Water pours into the living room ceiling through the poorly patched core holes. Not a single roofer will own up to causing the leak—leaving the homeowner in deep water and forced to scramble and sign a rushed, high-pressure replacement contract just to save their interior!
"We believe NO intrusive core sample should ever be cut into a property owner's roof unless it is permanently repaired to manufacturer specification AND paired with a comprehensive written engineering report that belongs 100% to the homeowner."
You should never let just any roofer cut into your roof without examining the entire roofing system first. That is why Rio Bravo Roofing LLC separates our services into two completely transparent, homeowner-first pathways:
We happily provide a detailed, accurate estimate without cutting a single hole in your roof. Our non-invasive assessment evaluates membrane thickness at terminations, parapet coping, stucco transitions, scupper/canale geometry, surface drainage, and fastener patterns—still far more thorough than almost any competitor's free estimate, with zero leak risk.
For a modest fee that covers the time and materials to properly execute and permanently patch a core sample, we perform a complete forensic audit of your roof system:
| Inspection Feature / Deliverable | Typical Competitor "Free Estimate + Core Cut" | Rio Bravo Option A: Non-Invasive Free Estimate ($0) | Rio Bravo Option B: Full Diagnostic Core & Slope Report (Small Fee) |
|---|---|---|---|
| Holes Cut Into Your Roof | Yes (Often patched hastily with caulk/mastic) | ZERO Holes Cut (100% Non-Invasive) | 1 Precision Core + Permanent Spec-Welded Patch |
| Written Core Stratigraphy Report Provided to Owner? | Rarely (Kept in salesperson's private notes) | Surface & Perimeter Written Proposal | Yes — Full Layer-by-Layer Photo & Deck Report |
| Intake & Exhaust Ventilation Engineering Math | Almost Never Calculated | Visual Assessment of Existing Vents | Full NFVA Intake/Exhaust Calculation Included |
| Direction of Slope & Ponding Deflection Mapping | Guessed by eye | Visual Ponding Ring & Scupper Check | Detailed Slope Direction Diagram & Cricket Plan |
| Can You Send Report to Other Roofers for Quotes? | No — Other roofers will cut more holes! | Detailed Scope of Work Proposal | YES! Universal Report for Apples-to-Apples Bids |
As we align our field operations with Versico Certified Installer standards, we proudly recommend Versico Roofing Systems (a premier division of Carlisle Construction Materials) as our primary single-ply partner for New Mexico homeowners and commercial building owners.
Versico's flagship VersiWeld® TPO is engineered with OctaGuard XT—comprising eight specialized heat- and UV-stabilizing antioxidants that withstand extreme solar radiation and heat aging at 240°F+ far longer than standard ASTM D6878 TPO sheets.
Whether installing standard .060-mil VersiWeld TPO or hail-resistant VersiFleece® TPO over rough wood or re-cover decks, Versico offers the industry's widest hot-air welding window—ensuring watertight seams even during crisp Santa Fe mornings or hot Albuquerque afternoons.
While Versico is our manufacturer of choice, Rio Bravo Roofing LLC has deep hands-on experience inspecting, repairing, detailing, and installing systems across the entire single-ply landscape—including legacy Firestone (now Holcim Elevate) roofs, Carlisle, GAF, Johns Manville, prefabricated Duro-Last, and architectural Sika Sarnafil. Click any manufacturer below to explore their official specs:
Known for VersiWeld® 60-mil TPO with OctaGuard XT™ weatherability technology. Exceptional resistance to New Mexico's high-altitude UV and thermal cycling, with industry-leading perimeter securement and hail-rated VersiFleece options.
Corporate sister brand to Versico and producer of Sure-Weld® TPO. Shares the renowned OctaGuard XT™ weathering chemistry and CAV-GRIP® 3V low-VOC spray contact adhesive system widely stocked at Albuquerque commercial supply houses.
Manufacturer of EverGuard® TPO and EverGuard Extreme® TPO (formulated specifically for extreme solar heat and rooftop solar arrays). Readily accessible through New Mexico distributors for both residential flat roofs and commercial buildings.
Formerly known as Firestone Building Products, Holcim Elevate manufactures UltraPly™ TPO and ISOGARD™ polyiso insulation. Thousands of existing New Mexico commercial and residential roofs carry legacy Firestone/Elevate membranes that we routinely service, repair, and replace.
A historic building-envelope powerhouse offering JM TPO in 45, 60, and 80 mil alongside ENRGY 3® Polyiso and Securock®/Fesco cover boards. Known for strong thickness-over-scrim ratios and complete single-source commercial assemblies.
Duro-Last uses factory-prefabricated PVC sheets (40, 50, 60 mil)—great for restaurant grease roofs, though often pricier and reliant on mechanically fastened "billowing" sheets. Sika Sarnafil (S327 / G410 PVC) is an ultra-premium institutional PVC system that typically costs 35–60% more than 60-mil TPO.
Use these four exhaustive technical matrices to compare membrane manufacturers, attachment configurations, insulation/cover board/ventilation assemblies, and warranty structures for New Mexico's climate.
| Manufacturer | Flagship Membrane Line | Chemistry | Mil Options (Winner in Bold) | UV / Heat Stabilizer Tech | NM Climate & Budget Verdict | Warranty Range | Official Link |
|---|---|---|---|---|---|---|---|
|
★ Preferred Partner Versico Roofing Systems |
VersiWeld® TPO & VersiFleece® TPO | TPO | .045, .060 (Winner), .080 + 100/115/135 Fleece | OctaGuard XT™ (8-part antioxidant/HALS UV package) | 9.9/10 Best Overall Value: Unbeatable UV endurance at 5,000+ ft + wide weld window. | 15, 20, 25, 30 Yr NDL | versico.com ↗ |
| Carlisle SynTec Systems | Sure-Weld® TPO & FleeceBACK® | TPO | .045, .060 (Winner), .080 + FleeceBACK | OctaGuard XT™ Weathering Package | 9.8/10 Tier-1 Sister Line: Identical polymer heritage to Versico; widely proven across NM. | 15, 20, 25, 30 Yr NDL | carlislesyntec.com ↗ |
| GAF Commercial | EverGuard® TPO & EverGuard Extreme® | TPO | .045, .060 (Winner), .080 + Fleece-Back | Advanced HALS & Extreme Solar Thermal Stabilizers | 9.4/10 Strong Local Supply: Great budget-friendly 60-mil option for residential & solar roofs. | 15, 20, 25, 30 Yr | gaf.com ↗ |
| Holcim Elevate (Formerly Firestone) | UltraPly™ TPO & UltraPly XR | TPO | .045, .060 (Winner), .080 + XR Fleece | Elevate Proprietary UV & Thermal Antioxidants | 9.3/10 Commercial Staple: Massive existing footprint in NM; supple handling on parapets. | 15, 20, 25, 30 Yr Red Shield | holcimelevate.com ↗ |
| Johns Manville (JM) | JM TPO & JM FleeceBack TPO | TPO | .045, .060 (Winner), .080 | High Thickness-Over-Scrim (TOS) UV Cap | 9.2/10 Full-Envelope Spec: Excellent when paired with JM polyiso & cover boards. | 15, 20, 25, 30 Yr Peak Advantage | jm.com ↗ |
| Duro-Last | Duro-Last® Custom Prefab & Duro-Tuff® | PVC Copolymer | 40 mil, 50 mil, 60 mil | Plasticizer-stabilized PVC w/ heavy weft-insertion scrim | Best for Restaurant Grease: Factory-welded deck sheets, but higher cost than 60-mil TPO. | 15, 20, 25, 30 Yr | duro-last.com ↗ |
| Sika Sarnafil | Sarnafil® S327 & G410 | Premium PVC | 48 mil, 60 mil, 72 mil, 80 mil | Lacquer-coated top surface + fiberglass/poly scrim | Institutional Budget Only: Exceptional longevity, but 35–60% more expensive than 60-mil TPO. | 20, 25, 30 Yr | usa.sika.com ↗ |
How your 60-mil TPO membrane is secured to the insulation and structural deck determines wind noise, hail resistance, and total budget.
| Attachment Configuration | How It Works | NM Wind Uplift & Flutter | NM Hail Performance | Relative Cost Index | Best Residential vs. Commercial Fit |
|---|---|---|---|---|---|
| 1. Fully Adhered 60-Mil TPO ★ Top Residential Choice | Insulation/cover board is mechanically fastened to the deck; 60-mil TPO is bonded 100% across its underside using bonding adhesive or CAV-GRIP spray. | Zero Billowing / Flutter: Monolithic bond eliminates membrane flapping noise during 70+ mph NM spring winds. | Very High (especially over HD Polyiso or DensDeck cover board; no exposed fastener heads directly under membrane). | $$ (Moderate / Best Residential Value) | Ideal for NM Homes (Pueblo/Parapet): Quiet inside living spaces, clean flat appearance, high wind uplift rating. |
| 2. Mechanically Attached 60-Mil TPO Commercial Budget Leader | TPO sheets are rolled out and anchored along the seam laps using heavy-duty screws and barbed seam plates, then overlapped and hot-air welded. | High Uplift Strength, Some Billowing: Sheet can lift slightly ("billow") between fastener rows in high winds. | Good to High (Requires proper plate placement to avoid puncture over fastener heads). | $ (Most Budget-Friendly) | Best for Large Commercial Warehouses & Retail: Fast installation over steel or wood decks at lowest cost per sq. ft. |
| 3. Fleece-Back Adhered TPO (VersiFleece 115-mil) | 60-mil TPO factory-laminated to a 55-mil non-woven polyester fleece backing, adhered in two-part urethane foam adhesive or hot asphalt. | Extreme Wind Uplift Resistance: Frequently rated for 90–120+ mph wind speed warranties. | Superior (FM Severe Hail Rated): Fleece cushion absorbs up to 1.75"–2.0" hail impacts without splitting. | $$$ (Premium Upgrade) | Best for High-End Custom Santa Fe/ABQ Homes & Re-Covers: Separates incompatible substrates and maximizes hail defense. |
| 4. Induction-Welded (RhinoBond®) TPO | Special TPO-coated plates fasten the insulation down; an electromagnetic induction tool welds the underside of the TPO sheet directly to the grid of plates without adhesives. | Evenly Distributed Grid Load: Eliminates VOC adhesive odors while reducing sheet flutter compared to in-seam fastening. | High (Plates are recessed into cover board). | $$ to $$$ | Best for Schools, Medical & Cold-Weather Installs: Zero chemical fumes for occupied buildings; works in low temperatures. |
A TPO membrane is only as durable as the cover board, slope geometry, and moisture ventilation engineered beneath it.
| Assembly Layer / Consideration | Primary Material Options | Technical Spec / Code Metric | Why It Is Critical in New Mexico | Rio Bravo Recommendation |
|---|---|---|---|---|
| 1. Hail & Fire Cover Board (Directly Under TPO) |
• ½" High-Density (HD) Polyiso (100 psi) • ¼" or ½" Gypsum Board (DensDeck® Prime / Securock®) • Avoid raw wood fiberboard under adhered TPO |
Compressive strength: 80–110 psi (HD Polyiso) vs. 500–900 psi (Gypsum). Adds R-2.5 (HD Iso) or UL Class A Fire Rating (Gypsum). | Standard 20-psi polyiso crushes under foot traffic and spring hailstones. A cover board prevents hail from bruising the insulation and puncturing the TPO from below. | Use ½" HD Polyiso (e.g., Versico SecurShield HD) for light weight + R-2.5 boost, or DensDeck Prime for maximum hail/fire defense. |
| 2. Rigid Thermal Insulation (Above-Deck) |
• Polyisocyanurate (Polyiso) (20 psi or 25 psi) • Expanded Polystyrene (EPS) (requires thermal barrier/slip sheet) |
Polyiso delivers R-5.7 per inch (LTTR). IECC commercial code typically calls for R-25 to R-30 continuous above-deck insulation (two staggered layers). | On true Unvented Hot Roofs or commercial steel decks, staggered Polyiso stops thermal bridging. (Note: On residential vented Cold Roofs, never add top foam without addressing the vented cavity below!) | Install Polyiso with staggered joints on Hot Roofs so conditioned indoor heat/air never escapes through board seams. |
| 3. Slope Correction & Canale Drainage |
• Tapered Polyiso System (⅛" or ¼" per ft) • Tapered Saddles & Crickets between scuppers • Custom Welded Scupper Sleeves |
IBC / NM Building Code standard: ¼" per foot (2% slope) for new construction; minimum ⅛" per foot positive drainage so water drains within 48 hours. | Dead-flat NM roofs deflect under weight, creating ponding lakes behind parapet walls. Worse, builders often mount canales ½" higher than the roof deck, trapping permanent water around the scupper throat! | Our Diagnostic Report maps existing slope direction and designs tapered crickets to push water directly into recessed, heat-welded TPO scupper targets. |
| 4. Parapet / Viga Intake & Exhaust Ventilation |
• Soffit / Eave Intake Vents • Thru-Parapet Breather Vents • One-Way Static / Mushroom Exhaust Vents • Or Conditioned Unvented Assembly |
IRC Code Formula: 1 sq. ft. Net Free Ventilated Area (NFVA) per 150 sq. ft. of roof area (or 1:300 with balanced 50% intake / 50% exhaust & vapor retarder). | Enclosed flat roof cavities between the ceiling drywall and roof deck trap humid indoor winter air. Without balanced intake and exhaust—or proper above-deck dew-point control—moisture condenses on the cold underside of the deck, rotting rafters even when the TPO has zero leaks! | We calculate exact intake & exhaust NFVA in square inches during our Full Diagnostic Inspection so your roof framing breathes properly. |
| 5. Structural Deck Substrates in NM |
• Plywood / OSB Sheathing • 2x6 / 2x8 Tongue & Groove (Viga/Latilla ceiling) • 22-ga / 20-ga Ribbed Steel Deck • Lightweight Insulating Concrete (LWIC) |
Fastener pull-out testing required on LWIC, gypsum, or aged wood decks. | On homes with exposed wood viga and latilla ceilings, long roofing screws driven carelessly will poke right through your living room ceiling! | We verify exposed viga ceilings before fastening and use adhesive/short-fastener base sheets to protect historic Southwestern interiors. |
Don't be fooled by vague "20-Year Warranty" promises on a quote. Here is what the three distinct types of flat roof warranties actually cover.
| Warranty Tier | Who Backs It? | Available Terms | What Is Actually Covered? | What Is Excluded / Catch? | Wind & Hail Riders |
|---|---|---|---|---|---|
| 1. Manufacturer Limited Material-Only Warranty Standard Residential & Light Commercial | Manufacturer (Versico, Carlisle, GAF, etc.) | 15 or 20 Years (60-mil TPO) | Covers replacement membrane material only if the TPO sheet itself prematurely degrades or fails due to a factory manufacturing defect. | Does NOT cover installation labor, flashing errors, or poorly welded seams. Often pro-rated over time. | Standard wind rating only; hail typically excluded unless upgraded. |
| 2. Manufacturer Full-System NDL (No Dollar Limit) Warranty ★ Commercial Gold Standard | Manufacturer (Requires Certified/Authorized Installer + Factory Field Inspection) |
• 15 Yr (.045/.060) • 20–25 Yr (.060 Winner) • 30 Yr (.080 / Fleece) |
Covers 100% of both Labor AND Materials with No Dollar Limit (un-prorated) to repair leaks caused by membrane, branded insulation, adhesives, flashings, OR workmanship defects—inspected and signed off by a factory technical representative. | Requires using 100% single-source manufacturer accessories (insulation, plates, adhesives) and paying a modest manufacturer inspection/warranty fee. |
Wind Riders: 55 mph standard; upgradable to 72, 80, 90, 100–120 mph. Hail Riders: 1" to 2" diameter hail coverage with HD cover board / Fleece-Back. |
| 3. Rio Bravo 2-Year Monsoon Workmanship Warranty + AMP Included on Every Residential & Commercial Install | Rio Bravo Roofing LLC (NM GS-21 Licensed) | 2 Full NM Monsoon Cycles (Extendable via AMP) | Directly guarantees our crew's hot-air seam welds, canale/scupper target detailing, mechanical aluminum parapet termination bars, counterflashing, and pipe boot penetrations against leaks. | Excludes third-party mechanical damage (e.g., HVAC technicians dropping compressors or satellite dish screws drilled through the TPO). | Paired alongside your manufacturer membrane warranty for dual protection. |
Enter your roof's approximate size and current condition below. Our interactive calculator instantly computes your IRC/IBC Intake & Exhaust Ventilation requirements, recommends the optimal budget-friendly TPO assembly, and helps you choose between our Free Non-Invasive Estimate ($0) and our Full Diagnostic Core & Slope Report.
Delivers 24+ mils of OctaGuard XT™ UV weathering protection above the scrim, zero wind-flutter noise inside your home, and supple hand-welded detailing into residential canales and parapet walls.
Balanced Split: 1,056 sq. in. Intake (soffit/parapet louver) + 1,056 sq. in. Exhaust (roughly 15–20 static breather vents depending on throat NFVA).
Verify positive slope toward scuppers; install tapered polyiso crickets between canales to eliminate 48-hour monsoon ponding zones.
Because your existing roof layers are unknown and you want quotes from multiple roofers, do NOT let 3 or 4 estimators cut "free estimate" holes in your roof. We will perform ONE properly welded/sealed core sample, calculate your exact ventilation & slope direction, and hand you the complete report so you can send it to any contractor you want for apples-to-apples pricing!
Review your configured parameters below and launch our 3-minute Preliminary Satellite Roof Assessment Form, call us directly, or send your specs via email.